Product Description
AMPTRON® 24V 150Ah Lithium LiFePO4 Batteries are an alternative replacement (AR) for most applications currently using a deep cycle Gel, AGM or Flooded Lead Acid battery. The maximum continuous discharge current is 175A and peak discharge current 320A for 5 seconds.
Our batteries come with a 4 year warranty and are designed using only the highest quality components. This includes the use of a robust Battery Protection System (BPS), aluminum encased prismatic cells, solid busbar connectors and a solid frame to reduce movement and damaging vibrations. AMPTRON® batteries can also be placed on its sides without the risk of components coming loose or loss of usable capacity.
Our Lithium batteries use a high quality robust integrated Battery Protection System (BPS) and is designed to manage and control all the battery protection requirements. The BPS maximises the performance of the battery by automatically balancing the cells and protecting them from being over charged or over discharged. Our integrated BPS design is what allows our batteries to be used as an AR "Alternative Replacement" for most applications requiring durable, high quality, dependable and lightweight Lithium Batteries.
Item
|
Specification
|
Description/Remark
|
Model
|
AT-LFP-24-150BV01
|
24V 150Ah / 175A Lithium LiFePO4 battery
|
Chemistry
|
Lithium Iron Phosphate (LiFePO4)
|
|
Battery dimensions
|
L-520mm x W-268mm x H-228mm
|
L x W x H
|
Weight
|
31kg
|
|
Cell type
|
3.2V 100Ah Prismatic cells
|
|
Battery module
|
8 pcs 3.2V 150Ah cells, 1 parallel and 8 serial
|
|
Casing material for single cell
|
Nickel plated steel
|
|
Standard capacity(0.2C5A)
|
24V 150Ah / 3840Wh
|
|
Cycle life
|
> 2000 cycles at 100% Depth of Discharge (DoD)
|
Under normal usage where the DOD is <80%, cycle life is expected to be up to 5000 cycles
|
Rated voltage
|
25.6V
|
Working voltage per cell: 3.2V
|
Charge voltage
|
29.2 V
|
Max. charge voltage per cell: 3.60V
|
Cut-off volate
|
2.5V for lowest cell, Nominal 20V
|
Cut-off is triggered when the first cell reaches 2.50V
|
Depth of discharge (DoD)
|
100%
|
Batteries can be discharged to 100% of the rated capacity
|
Optimum charge current
|
20A (0.2C5A)
|
Cell max voltage﹤3.9V
|
Charging time
|
Approximately 5 hours
|
When charging from low voltage cut-off point
|
Charge current range
|
30A (0.2C) to 100A (0.67C)
|
Cell max voltage < 3.9V
|
Rapid charging
|
Max. charge current 136A (0.91C)
|
Temperature increase falling within 15°C is normal. Over 15°C will affect the service life of the cells.
|
Max continuous discharge current
|
175A
|
1.17C
|
Peak discharge current
|
320A
|
2.13C (5 seconds)
|
Discharge performance in normal temperature
|
20A (0.2C3A) ≥ 100%
1C3A ≥90% |
|
Operating temperatures
|
Charge 0℃~45℃
Discharge -20℃~65℃ Storage -20℃~45℃ |
|
Impedance (Max, at 1000Hz.)
|
≤ 20mΩ
|
|
Storage performance
|
Capacity can be kept ≥ 80% in storage for 12months
|
Battery should be kept at -20℃ ~ 45℃ where it’s dry, clean and well-ventilated.
|
Connecting Terminals Pos (+) & Neg (-)
|
M8
|
|
Ingress Protection (IP Rating)
|
IP 65
|
|