Product Description
AMPTRON® 12V 200Ah / 175A Lithium LiFePO4 Batteries are an alternative replacement (AR) for any application currently using a deep cycle Gel, AGM or Flooded Lead Acid battery. The maximum continuous discharge current is 175A and peak discharge current 320A for 5 seconds.
Our Lithium batteries use a high quality robust integrated Battery Protection System (BPS) and is designed to manage and control all the battery protection requirements. The BPS maximizes the performance of the battery by automatically balancing the cells and protecting them from being over charged or over discharged. Our integrated BPS design is what allows our batteries to be used as an AR "Alternative Replacement" for any application requiring durable, high quality, dependable and lightweight Lithium Batteries.
We use these batteries exclusively in our world class Northern Lite Slide on Truck Campers.
Our Lithium batteries use a high quality robust integrated Battery Protection System (BPS) and is designed to manage and control all the battery protection requirements. The BPS maximizes the performance of the battery by automatically balancing the cells and protecting them from being over charged or over discharged. Our integrated BPS design is what allows our batteries to be used as an AR "Alternative Replacement" for any application requiring durable, high quality, dependable and lightweight Lithium Batteries.
Item
|
Specification
|
Description/Remark
|
Model
|
AT-LFP-12-200BV02
|
12V 200Ah / 175A Continuous Discharge Lithium LiFePO4 battery
|
Chemistry
|
Lithium Iron Phosphate (LiFePO4)
|
|
Battery dimensions
|
L-345mm x W-190mm x H-245mm
|
|
Weight
|
22kg
|
|
Cell type
|
3.2V 100Ah Prismatic cells
|
|
Battery module
|
8 pcs 3.2V 100Ah cells, 2 parallel strings of 4 cells in series
|
|
Casing material for single cell
|
Nickel plated steel
|
|
Standard capacity(0.2C5A)
|
200Ah / 2560Wh
|
|
> 2000 cycles at 100% Depth of Discharge (DoD)
|
Cycle life
|
Under normal usage where the DOD is <80%, cycle life is expected to be up to 5000 cycles
|
Rated voltage
|
12.8V
|
Working voltage per cell: 3.2V
|
Charge voltage
|
14.4 - 14.6V
|
Max. charge voltage per cell: 3.65V
|
Cut-off volate
|
2.5V for lowest cell, nominal 10V
|
Cut-off is triggered when the first cell reaches 2.50V
|
Depth of discharge (DoD)
|
100%
|
Batteries can be discharged to 100% of the rated capacity
|
Standard charge current
|
40A
|
0.2C
|
Charging time
|
Approximately 5 hours
|
When charging from low voltage cut-off point
|
Optimum charge current range
|
20A (0.2C5A) to 100A (1C3A)
|
Cell max voltage < 3.9V
|
Rapid charging
|
Max. charge current 200A (1C3A)
|
Temperature increase falling within 15°C is normal. Over 15°C will affect the service life of the cells.
|
Max continuous discharge current
|
175A
|
1C, cell min voltage> 2.0v
|
Peak discharge current
|
320A
|
2C (5 seconds)
|
Discharge performance in normal temperature
|
20A (0.2C3A) ≥ 100%
1C3A ≥90% |
|
Operating temperatures
|
Standard 0℃~45℃
Discharge -20℃~65℃ Storage -20℃~45℃ |
|
Impedance (Max, at 1000Hz.)
|
≤ 45mΩ
|
|
Storage performance
|
Capacity can be kept ≥ 80% in storage for 12months
|
Battery should be kept at -20℃ ~ 45℃ where it’s dry, clean and well-ventilated.
|
Connecting Terminals Pos (+) & Neg (-)
|
M8
|
|
Ingress Protection (IP Rating)
|
IP 65
|